Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/11254
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Aleixo, Herbert | - |
dc.creator | Saczk, Adelir Aparecida | - |
dc.creator | Oliveira, Marcelo Firmino de | - |
dc.creator | Okumura, Leonardo Luiz | - |
dc.date.accessioned | 2016-06-14T13:38:55Z | - |
dc.date.available | 2016-06-14T13:38:55Z | - |
dc.date.issued | 2016-06-14 | - |
dc.identifier.citation | ALEIXO, H. et al. Determination of tetradifon in brazilian green bell pepper by differential pulse voltammetry. Journal of The Electrochemical Society, Baltimore, v. 159, n. 7, p. B775-B781, 2012. | pt_BR |
dc.identifier.uri | http://jes.ecsdl.org/content/159/7/B775.abstract | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/11254 | - |
dc.description.abstract | Tetradifon, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to green bell pepper crops. In this context, in this work, a reliable and sensitive method for determination of tetradifon in Brazilian green bell pepper samples involving a differential pulse voltammetry (DPV) technique on a glassy carbon electrode is proposed. The electrochemical behavior of tetradifon as followed by cyclic voltammetry (CV) suggests that its reduction occurs via an irreversible five–electron transfer vs. Ag|AgCl, KCl 3 M reference electrode. Very well–resolved diffusion controlled voltammetric peaks have been obtained in a supporting electrolyte solution composed of a mixture of 40% dimethylformamide (DMF), 30% methanol, and 30% NaOH 0.3 mol L−1 at −1.43, −1.57, −1.73, −1.88, and −2.05 V. The proposed DPV method has a good linear response in the 3.00 – 10.0 μmol L−1 range, with a limit of detection (L.O.D) of 0.756 μmol L−1 and 0.831 μmol L−1 in the absence and in the presence of the matrix, respectively. Moreover, improved L.O.D results (0.607 μmol L−1) have been achieved in the absence of DMF from the supporting electrolyte solution. Recovery has been evaluated in five commercial green bell pepper samples, and recovery percentages ranging from 91.0 to 109 have been obtained for tetradifon determinations. The proposed voltammetric method has also been tested for reproducibility, repeatability, and potential interferents, and the results obtained for these three analytical parameters are satisfactory for electroanalytical purposes. | pt_BR |
dc.language | en_US | pt_BR |
dc.publisher | Electrochemical Society | pt_BR |
dc.rights | restrictAccess | pt_BR |
dc.source | Journal of The Electrochemical Society | pt_BR |
dc.title | Determination of tetradifon in brazilian green bell pepper by differential pulse voltammetry | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DQI - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.