Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/11268
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Fulgêncio, Ana Carolina da Costa | - |
dc.creator | Saczk, Adelir Aparecida | - |
dc.creator | Oliveira, Marcelo Firmino de | - |
dc.creator | Okumura, Leonardo Luiz | - |
dc.date.accessioned | 2016-06-16T12:43:47Z | - |
dc.date.available | 2016-06-16T12:43:47Z | - |
dc.date.issued | 2016-06-16 | - |
dc.identifier.citation | FULGÊNCIO, A. C. da C. et al. New voltammetry-based analytical method for indirect determination of procymidone in brazilian apples. Food Analytical Methods, [S.l.], v. 7, n. 1, p. 31-38, Jan. 2014. | pt_BR |
dc.identifier.uri | http://link.springer.com/article/10.1007%2Fs12161-013-9593-9 | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/11268 | - |
dc.description.abstract | Procymidone, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to apple crops. In this work, we propose a reliable and sensitive method to determine procymidone in Brazilian apples. The method involves differential pulse (DPV) and square-wave voltammetry (SWV) techniques on a glassy carbon electrode. In a supporting electrolyte solution of 0.5 mol L−1 NaOH, procymidone undergoes an irreversible one-electron oxidation at +1.42 V by cyclic voltammetric vs. Ag|AgCl, KCl 3 M reference electrode. The proposed DPV and SWV methods have a good linear response in the 8.00–20.0 mg L−1 range, with limits of detection (LOD) of 0.678 and 0.228 mg L−1, respectively, in the absence of the matrix. We obtained improved LOD (0.097 mg L−1) in the presence of apple matrix and the supporting electrolyte solution. We used three commercial apple samples to evaluate recovery, and we achieved recovery percentages ranging from 94.6 to 110 % for procymidone determinations. We also tested the proposed voltammetric method for reproducibility, repeatability, and potential interferents, and the results were satisfactory for electroanalytical purposes. | pt_BR |
dc.language | en_US | pt_BR |
dc.publisher | Springer US | pt_BR |
dc.rights | restrictAccess | pt_BR |
dc.source | Food Analytical Methods | pt_BR |
dc.subject | Procymidone | pt_BR |
dc.subject | Brazilian apples | pt_BR |
dc.subject | Differential pulse voltammetry | pt_BR |
dc.subject | Square-wave voltammetry | pt_BR |
dc.title | New voltammetry-based analytical method for indirect determination of procymidone in brazilian apples | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DQI - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.