Buscar

 

RI UFLA (Universidade Federal de Lavras) >
DEG - Departamento de Engenharia >
DEG - Artigos publicados em periódicos >

Please use this identifier to cite or link to this item: http://repositorio.ufla.br/jspui/handle/1/15124

Title: Vulnerabilidade de tubos gotejadores ao entupimento por precipitados químicos de ferro
Other Titles: Vulnerability of drip hoses to clogging by chemical precipitates of iron
???metadata.dc.creator???: Costa, Claudionor Camilo da
Campos, Cláudio Milton Montenegro
Faria, Manuel Alves de
Keywords: Precipitados químicos
Sistemas de irrigação
Tubos gotejadores - Vulnerabilidade
Chemical precipitates
Irrigation systems
Drip Pipes - Vulnerability
Publisher: Instituto Federal de Educação, Ciência e Tecnologia do Sul de Minas Gerais
Issue Date: Apr-2010
Citation: COSTA, C. C. da; CAMPOS, C. M. M., FARIA, M. A. de. Vulnerabilidade de tubos gotejadores ao entupimento por precipitados químicos de ferro. Revista Agrogeoambiental, Pouso Alegre, v. 2, n. 1, p. 18-27, abr. 2010.
???metadata.dc.description.resumo???: Objetivou-se, com o presente trabalho, verificar a intensidade da ocorrência dos precipitados químicos em cinco modelos de tubos gotejadores submetidos à irrigação com água contendo alto teor de ferro total. O sistema de irrigação foi composto de um reservatório de 1000L, um conjunto motobomba de 0,5 cv, um filtro de disco de 120 mesh, uma bancada de testes onde foram instaladas os tubos gotejadores. O sistema foi avaliado calculando-se a Vazão Média, Coeficiente de Variação de Vazão(C.V.Q.), Uniformidade de Distribuição/Emissão (U.D./U.E.) e Vazão Relativa (V.R.). Observou-se ao longo do experimento e no final do mesmo (ao redor de 400 h de irrigação) que os precipitados químicos de ferro comprometeram o desempenho de todos os tubos gotejadores, promovendo grande redução da vazão dos emissores. O grau e a intensidade de entupimento variaram conforme o modelo, notando-se que as marcas que exigiam filtração mais rigorosa (R e C) e aspectos construtivos semelhantes-Labirintos: R, Q e C se mostraram mais susceptíveis ao entupimento. Dentro das condições de estudo deste experimento, concluiu-se que a utilização de água com este teor de ferro total (3 mg.L-1) mostrou-se impraticável, podendo comprometer a irrigação.
Abstract: This research aimed to verifying the intensity of chemical precipitates in five different drip hoses models on water containing a high amount of total iron. The irrigation system was assembled with one reservoir of 1000 L, a set of motor pump of 0.5 cv, a 120 mesh filter disk, a test banch measuring where it was installed the drip hoses. The system was evaluated estimating the average flow rate, variation flow coeffícient (VFC), uniformity of distribution/emission and relative flow rate. It was possible to observe, during the days of the tests, and also at the end of the research (around 400 h of irrigation), that the chemical sediments of iron, deterioreted the performance of the drip hoses, promoting a great reduction in their flowing. The degree and the intensity of obstruction varied according to the model, observing that the makes which demanded more strictly fíltration (R and C), with a similar design aspects, labyrinths: R, Q and C, showed to be more susceptible to clogging problems. In the studies conditions it could be concluded, that the utilization of water, with that total iron concentration (3 mg.L-1), showed to compromise the irrigation performance.
URI: http://repositorio.ufla.br/jspui/handle/1/15124
???metadata.dc.language???: pt_BR
Appears in Collections:DEG - Artigos publicados em periódicos

Files in This Item:

File Description SizeFormat
ARTIGO_Vulnerabilidade de tubos gotejadores ao entupimento por precipitados químicos de ferro.pdf1.23 MBAdobe PDFView/Open

This item is licensed under a Creative Commons License
Creative Commons

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.


View Statistics

 


DSpace Software Copyright © 2002-2010  Duraspace - Feedback