Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/29187
Título: Desempenho de filtros anaeróbios no tratamento de águas residuárias da lavagem e descascamento dos frutos do cafeeiro
Título(s) alternativo(s): Performance of the anaerobic filters in the treatment of wastewater from the washing and pulping/husking the cherries of the coffee shrub
Palavras-chave: Reator anaeróbio
Filtro anaeróbio
Compostos fenólicos
Águas residuárias - Tratamento
Anaerobic reactor
Anaerobic filter
Phenolic compounds
Wastewater - Treatment
Data do documento: Jan-2011
Editor: Universidade Federal de Viçosa
Citação: FIA, R. et al. Desempenho de filtros anaeróbios no tratamento de águas residuárias da lavagem e descascamento dos frutos do cafeeiro. Engenharia na Agricultura, Viçosa, MG, v. 19, n. 1, jan./fev. 2011.
Resumo: Three anaerobic filters with upflow were operationally evaluated for the treatment of wastewater from the coffee cherries processing (ARC). The reactors were made with PVC tube with total volume for 139.5 L. They were operated under environmental temperature varying from 13.8 to 24.4 ºC. The ARC had the pH corrected with whitewash to values up to 7 and the concentration of nutrients to relationship DBO/N/P equal 100/5/1. The volumetric organic load rate and hydraulic retention time varied from 1.49 to 12.99 kg m-3 d-1 and 32.3 to 56.9 h, respectively. The filters were monitored, by collecting both the affluent and effluent samples of the filters, and quantifying the variables: COD, BOD, phenolic compounds, pH, alkalinity and volatile acids. At the end of the evaluated conditions it observed that the great oscillation in the hydraulic and organic load did with that the anaerobic filters used in this work operated in an unstable condition, presenting unbalance between the producers and consumers of volatile acids, with production no satisfactory of alkalinity bicarbonate. However, the affluent and effluent pH values were inside of the range of appropriate values so that it has the anaerobic degradation of the organic material. The filters didn’t support the organic shock load rate, what reduced the efficiency of removal of organic matter drastically and phenolic compounds. Based on the results of performance and conditions operational, it is conclude that the maximum organic load rate to be applied in anaerobic filters for treatment of ARC, it should not exceed 2 kg m-3 d-1 of DQO.
URI: http://www.seer.ufv.br/seer/index.php/reveng/article/view/277
http://repositorio.ufla.br/jspui/handle/1/29187
Aparece nas coleções:DEG - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.