Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/29814
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Viana, D. C. | - |
dc.creator | Pires, J. F. | - |
dc.creator | Braga, R. A. | - |
dc.date.accessioned | 2018-07-27T13:59:12Z | - |
dc.date.available | 2018-07-27T13:59:12Z | - |
dc.date.issued | 2017-07 | - |
dc.identifier.citation | VIANA, D. C.; PIRES, J. F.; BRAGA, R. A. Biospeckle laser technique applied for estimating disinfection accomplishment of wastewaters subjected to chlorination. Process Safety and Environmental Protection, Rugby, v. 109, p. 670-676, July 2017. | pt_BR |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0957582017301805#! | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/29814 | - |
dc.description.abstract | Despite the undesirable effects of its byproducts, such as the formation of trihalomethanes, chlorination is the most widely used method of disinfection in the Wastewater Treatment Plants (WWTPs) worldwide. Therefore, besides reducing the labor cost of this treatment stage, the automatic product dosage as calcium hypochlorite may increase its efficiency, avoiding wastage and reducing its unwanted effects. To accomplish it, a digital controller needs to be constantly fed with information that allows it to estimate the disinfection potential of the process, which traditionally occurs by means of gauges that concomitantly appraise the Oxidation–Reduction Potential (ORP) and the pH of the water in analysis. In this work, the technique known as biospeckle laser was investigated as an alternative to support the measurements required for an automatic chlorination system, performing the correlation between the biological activity level and the presence/inactivation of pathogenic microorganisms in samples of water collected after the biological treatment stage of a WWTP. Five treatment groups were analyzed by 16 replications and the responses were consistent when compared with those obtained using standard methods for this sort of analysis, demonstrating that the investigated technique is feasible for the desired purpose, indicating if the disinfection is being satisfactory or not. | pt_BR |
dc.language | en_US | pt_BR |
dc.publisher | Elsevier | pt_BR |
dc.rights | restrictAccess | pt_BR |
dc.source | Process Safety and Environmental Protection | pt_BR |
dc.subject | Biospeckle | pt_BR |
dc.subject | Wastewater treatment | pt_BR |
dc.subject | Chlorination | pt_BR |
dc.subject | Tratamento de águas residuais | pt_BR |
dc.subject | Cloração | pt_BR |
dc.title | Biospeckle laser technique applied for estimating disinfection accomplishment of wastewaters subjected to chlorination | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DEG - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.