Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/30257
Registro completo de metadados
Campo DCValorIdioma
dc.creatorFelix, Fabiana S.-
dc.creatorDaniel, Daniela-
dc.creatorMatos, Jivaldo R.-
dc.creatorLago, Claudimir Lucio do-
dc.creatorAngnes, Lúcio-
dc.date.accessioned2018-08-30T13:30:01Z-
dc.date.available2018-08-30T13:30:01Z-
dc.date.issued2016-07-20-
dc.identifier.citationFELIX, F. S. et al. Fast analysis of terbutaline in pharmaceuticals using multi-walled nanotubes modified electrodes from recordable compact disc. Analytica Chimica Acta, Amsterdam, v. 928, p. 32-38, 20 July 2016.pt_BR
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0003267016305189?via%3Dihub#!pt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/30257-
dc.description.abstractIn this study, homemade disposable gold electrodes made from recordable compact disks were modified with carbon nanotubes for amperometric quantification of terbutaline sulfate in pharmaceutical products. A flow cell using an impingent jet of solution on the electrode surface was build and used for amperometric detection, and a series of experiments were carried out to find the best experimental conditions for the new electrode in a specially designed cell. A linear response for terbutaline was obtained in the range from 3.0 × 10−6 to 5.0 × 10−4 mol L−1 (at 0.63 V vs. Ag/AgCl). The limits of detection and quantification were calculated as 5.8 × 10−7 mol L−1 (S/N = 3) and 1.9 × 10−6 mol L−1 (S/N = 10), respectively. A frequency of 30 injections h−1 was attained. The proposed method was successfully applied to the analyses of commercial syrup samples, and all results were in good agreement with those obtained by using high performance liquid chromatography and capillary electrophoresis-tandem mass spectrometrypt_BR
dc.languageen_USpt_BR
dc.publisherElsevierpt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceAnalytica Chimica Actapt_BR
dc.subjectMulti-walled nanotubespt_BR
dc.subjectGold electrodes from recordable compact discpt_BR
dc.subjectTerbutalinept_BR
dc.subjectAmperometrypt_BR
dc.subjectImpingent flowing systempt_BR
dc.subjectNanotubos de paredes múltiplaspt_BR
dc.subjectEletrodos de ouro de discos compactos graváveispt_BR
dc.titleFast analysis of terbutaline in pharmaceuticals using multi-walled nanotubes modified electrodes from recordable compact discpt_BR
dc.typeArtigopt_BR
Aparece nas coleções:DQI - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.