Título: | Geoestatística aplicada a distribuição espacial das condições térmicas e ruído em instalações Compost Barn com diferentes sistemas de ventilação |
Título(s) alternativo(s): | Geostatistics applied to spatial distribution of thermal conditions and noise in Compost Barn systems with different ventilation systems |
Palavras-chave: | Bovinocultura de leite Bem-estar animal Pressão sonora Animal welfare Sound pressure |
Data do documento: | 2016 |
Editor: | Fundação de Ensino Superior de Passos |
Citação: | OLIVEIRA, C. E. A. et al. Geoestatística aplicada a distribuição espacial das condições térmicas e ruído em instalações Compost Barn com diferentes sistemas de ventilação. Ciência et Praxis, Passos, v. 9, n. 18, 2016. |
Resumo: | The objective of this work was to evaluate the distribution of thermal comfort and noise levels in Compost Barn installations with different ventilation systems, through the geostatistical technique. The experiment was conducted in April 2017, in two farms located in Madre de Deus – MG. Three installations with different ventilation systems were evaluated: natural ventilation; low-volume, high-speed mechanical ventilation (LVHS); and mechanical ventilation of high volume and low speed (HVLS). The interior of the facilities was divided into meshes of 40 equidistant points, in which the levels of Air Temperature (Tar), Relative Humidity (RH) and Noise were collected manually, and such collections were always performed in the afternoon. The geostatistical technique was used for to evaluate the dependence and spatial distribution of Temperature and Humidity Index (THI) and noise levels. The results found evidenced the occurrence of strong spatial dependence for both variables and facilities. The highest levels of THI were observed for installation with natural ventilation, while the highest levels of noise were verified for installation with LVHS type ventilation, and the installation with HVLS type ventilation showed low spatial variability. |
URI: | http://revista.uemg.br/index.php/praxys/article/view/2626 http://repositorio.ufla.br/jspui/handle/1/30941 |
Aparece nas coleções: | DEG - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.