Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/33016
Título: Identifying obstructive sleep apnoea patients responsive to supplemental oxygen therapy
Palavras-chave: Oxygen therapy
Obstructive sleep apnea - Treatment
Clinical polysomnography
Oxigenoterapia
Apnéia do sono obstrutiva - Tratamento
Polissonografia clínica
Data do documento: 2018
Editor: European Respiratory Society
Citação: SANDS, S. A. et al. Identifying obstructive sleep apnoea patients responsive to supplemental oxygen therapy. European Respiratory Journal, Copenhagen, v. 52, n. 3, 2018. doi: 10.1183/13993003.00674-2018.
Resumo: A possible precision-medicine approach to treating obstructive sleep apnoea (OSA) involves targeting ventilatory instability (elevated loop gain) using supplemental inspired oxygen in selected patients. Here we test whether elevated loop gain and three key endophenotypic traits (collapsibility, compensation and arousability), quantified using clinical polysomnography, can predict the effect of supplemental oxygen on OSA severity. 36 patients (apnoea–hypopnoea index (AHI) >20 events·h−1) completed two overnight polysomnographic studies (single-blinded randomised-controlled crossover) on supplemental oxygen (40% inspired) versus sham (air). OSA traits were quantified from the air-night polysomnography. Responders were defined by a ≥50% reduction in AHI (supine non-rapid eye movement). Secondary outcomes included blood pressure and self-reported sleep quality. Nine of 36 patients (25%) responded to supplemental oxygen (ΔAHI=72±5%). Elevated loop gain was not a significant univariate predictor of responder/non-responder status (primary analysis). In post hoc analysis, a logistic regression model based on elevated loop gain and other traits (better collapsibility and compensation; cross-validated) had 83% accuracy (89% before cross-validation); predicted responders exhibited an improvement in OSA severity (ΔAHI 59±6% versus 12±7% in predicted non-responders, p=0.0001) plus lowered morning blood pressure and “better” self-reported sleep. Patients whose OSA responds to supplemental oxygen can be identified by measuring their endophenotypic traits using diagnostic polysomnography.
URI: https://erj.ersjournals.com/content/52/3/1800674
http://repositorio.ufla.br/jspui/handle/1/33016
Aparece nas coleções:DNU - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.