Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/36658
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Abreu, Daiane Cássia Pereira | - |
dc.creator | Botrel, Bianca Mesquita Coelho | - |
dc.creator | Bazana, Matheus Julien Ferreira | - |
dc.creator | Rosa, Priscila Vieira e | - |
dc.creator | Sales, Priscila Ferreira | - |
dc.creator | Marques, Márcio da Silva | - |
dc.creator | Saczk, Adelir Aparecida | - |
dc.date.accessioned | 2019-09-05T19:14:37Z | - |
dc.date.available | 2019-09-05T19:14:37Z | - |
dc.date.issued | 2019-01-01 | - |
dc.identifier.citation | ABREU, D. C. P. et al. Development and comparative analysis of single-drop and solid-phase microextraction techniques in the residual determination of 2-phenoxyethanol in fish. Food Chemistry, London, v. 270, p. 487-493, 1 Jan. 2019. | pt_BR |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0308814618312822#! | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/36658 | - |
dc.description.abstract | Solid-phase microextraction (SPME) and single-drop microextraction (SDME) in headspace mode, were used in the residual determination of the anesthetic 2-phenoxyethanol in fish fillets, to ensure food safety. For the optimization of the methodologies the experimental central composite design (CCD) was used, resulting in accurate evaluations with less amount of analysis. The developed methodologies presented good precision in the evaluated range, o limits of detection (LD) and quantification (LQ) for SDME were 0.2 and 0.62 μg mL−1 and for SPME were 0.18 and 0.56 μg mL−1, respectively. In the analyzed samples the determined elimination time of post-anesthesia 2-phenoxyethanol was 12 h for the SDME and 24 h for the SPME, at the anesthesia concentrations evaluated (450–1050 μg mL−1). The two techniques presented viability of application for the residual determination of 2-phenoxyethanol in fish, SPME being more sensitive and automated and SDME with lower operation cost. | pt_BR |
dc.language | en_US | pt_BR |
dc.publisher | Elsevier | pt_BR |
dc.rights | restrictAccess | pt_BR |
dc.source | Food Chemistry | pt_BR |
dc.subject | Solid-phase microextraction | pt_BR |
dc.subject | Aquaculture | pt_BR |
dc.subject | Single-drop microextraction | pt_BR |
dc.subject | Food safety | pt_BR |
dc.subject | Microextração em fase sólida | pt_BR |
dc.subject | Aquicultura | pt_BR |
dc.subject | Microextração de gota única | pt_BR |
dc.subject | Segurança alimentar | pt_BR |
dc.title | Development and comparative analysis of single-drop and solid-phase microextraction techniques in the residual determination of 2-phenoxyethanol in fish | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DQI - Artigos publicados em periódicos DZO - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.