Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/40208
Título: Modeling and simulation of anion exchange chromatography for purification of proteins in complex mixtures
Palavras-chave: Protein purification
Anion exchange chromatography
Mathematical modeling
Complex protein mixture
Steric mass action isotherm
Equilibrium dispersive model
Data do documento: Fev-2020
Editor: Elsevier
Citação: BENEDINI, L. J. et al. Modeling and simulation of anion exchange chromatography for purification of proteins in complex mixtures. Journal of Chromatography A, [S.l.], v. 1613, Feb. 2020.
Resumo: Ion exchange chromatography is extensively used in the purification of biological compounds. Reliable mathematical models describing this chromatographic technique are available and can be used to improve the performance of this separation step. However, the use of synthetic mixtures for model development hampers the application of this approach with real cell extracts processed in downstream operations. This work presents an original approach for handling non-synthetic genuine mixtures of proteins, which was applied in the purification of an untagged recombinant pneumococcal surface protein A (PspA4Pro). First, evaluation was made of the efficiency of steric mass action (SMA) and modified Langmuir isotherms, which were separately used together with the equilibrium dispersive model (EDM). The data used for parameter estimation and model validation were obtained from anion exchange chromatography runs (employing Q-Sepharose FF), applied to real cell extracts produced by different cultivation strategies. Simulations showed that the models were able to describe the complex mixtures of unknown proteins. Next, the EDM and SMA approaches were used to separately describe the profile of PspA4Pro and the pool of protein impurities eluted together. The simulations showed that PspA4Pro tended to elute at the beginning of the peak, enabling the establishment of an alternative elution schedule that provided a 34% increase in the purity achieved using the anion exchange chromatography.
URI: https://www.sciencedirect.com/science/article/abs/pii/S0021967319311148
http://repositorio.ufla.br/jspui/handle/1/40208
Aparece nas coleções:DEG - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.