Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/57704
Registro completo de metadados
Campo DCValorIdioma
dc.creatorReis, Gisele F. M. dos-
dc.creatorNogueira, Rodrigo B.-
dc.creatorOberlender, Guilherme-
dc.creatorMuzzi, Ruthnéa A. L.-
dc.creatorMantovani, Matheus M.-
dc.date.accessioned2020-10-21T18:34:22Z-
dc.date.accessioned2023-06-27T19:39:21Z-
dc.date.available2020-10-21T18:34:22Z-
dc.date.available2023-06-27T19:39:21Z-
dc.date.issued2014-
dc.identifier.citationREIS, G. F. M. dos et al. Spectral analysis of femoral artery blood flow waveforms of conscious domestic cats. Journal of Feline Medicine and Surgery, [S. l.], p. 1-7, 2014. DOI: 10.1177/1098612X14529123.pt_BR
dc.identifier.urihttps://journals.sagepub.com/doi/10.1177/1098612X14529123?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub%20%200pubmedpt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/57704-
dc.description.abstractThe qualitative and quantitative aspects of femoral artery blood flow waveform spectra were evaluated in 15 male and 15 female Persian and mixed breed domestic felines (Felis catus), which were healthy and not sedated, using duplex Doppler ultrasonography (DDU). Spectral Doppler demonstrated a biphasic characteristic in 16 (53.34%) of the animals evaluated, and a triphasic characteristic in the 14 (46.66%) remaining animals. The systolic blood pressure and heart rate values were within the normal range for the species. The quantitative parameters evaluated, based on the spectral Doppler, were as follows: systolic velocity peak (SVP), recent diastolic velocity peak (RDVP), end diastolic velocity peak (EDVP), mean velocity (MV), integral velocity time (ITV), artery diameter (AD), femoral flow volume (FFV), pulsatility index (PI), resistive index (RI), systolic peak acceleration time (AT), and deceleration time (DT). The respective mean values were: 36.41 ± 7.33 cm/s, 4.69 ± 0.90 cm/s, 10.74 ± 2.74 cm/s, 23.06 ± 4.86 cm/s, 3.91 ± 1.05 cm, 0.17 ± 0.04 cm, 0.11 ± 0.08 cm3, 3.85 ± 0.19, 1.40 ± 0.20, 39.84 ± 7.38 ms, and 114.0 ± 22.15 ms. No significant differences were found between males and females. The analyses carried out on the femoral artery flow spectrum obtained by DDU showed that it is easy to use and highly tolerated in non-sedated, healthy felines. It appears that DDU may be a useful diagnostic technique, but further studies are needed to evaluate how it compares with invasive telemetric methodology or high-definition oscillometric waveform analytic techniques.pt_BR
dc.languageen_USpt_BR
dc.publisherSAGE Journalspt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceJournal of Feline Medicine and Surgerypt_BR
dc.subjectCats - Femoral arterypt_BR
dc.subjectBlood flowpt_BR
dc.subjectSpectral Dopplerpt_BR
dc.subjectGatos - Artéria femuralpt_BR
dc.subjectFluxo sanguíneopt_BR
dc.subjectSpectral Dopplerpt_BR
dc.titleSpectral analysis of femoral artery blood flow waveforms of conscious domestic catspt_BR
dc.typeArtigopt_BR
Aparece nas coleções:DMV - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.