Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/58179
Registro completo de metadados
Campo DCValorIdioma
dc.creatorTrugilho, Paulo Fernando-
dc.creatorMarconato, Daniellle Gomes-
dc.creatorMassuque, Jonas Zefanias-
dc.creatorMazzuchi, Natalia Moraes-
dc.creatorSalgado, Thaiane de Abreu-
dc.creatorSilva, Paulo Henrique Muller da-
dc.date.accessioned2023-07-21T18:50:09Z-
dc.date.available2023-07-21T18:50:09Z-
dc.date.issued2023-
dc.identifier.citationTRUGILHO, P. F. et al. Equilibrium moisture content in charcoal exposed to different relative humidity conditions. Treedimensional, [S.l.], v. 10, 2023.pt_BR
dc.identifier.urihttps://treedimensional.org/archives/42pt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/58179-
dc.description.abstractEquilibrium moisture content is an important characteristic associated with hydrocarbon fuels, including biomass and charcoal. Its determination is essential since it negatively affects several properties, especially the caloric value and energy density. Thus, this research was conducted with the aim of determining the equilibrium moisture content of charcoal produced for industrial purposes from 6-year-old Eucalyptus and Corymbia species exposed to different relative humidity conditions at a temperature of 30°C. Four samples of charcoal were collected from each of the four species of Eucalyptus and Corymbia used in the study. The equilibrium moisture content of the samples was always achieved by desorption. At the end of the experiment, the dry masses were obtained. Twelve simple and multiple linear models were used to estimate the equilibrium moisture of the samples. Overall average equilibrium moisture estimates were slightly higher in Eucalyptus species in all relative humidity conditions, except at 90%. Considering the scientific principle of parsimony, the simple linear model was selected for both Corymbia and Eucalyptus species. The difference between Corymbia and Eucalyptus equilibrium moisture of charcoal was higher at lower relative humidity conditions.pt_BR
dc.languagept_BRpt_BR
dc.publisherUniversidade Federal de Goiáspt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceTreedimensionalpt_BR
dc.subjectCâmara de climatizaçãopt_BR
dc.subjectHigroscopicidadept_BR
dc.subjectBiorredutorpt_BR
dc.subjectSiderurgiapt_BR
dc.subjectClimatic chamberpt_BR
dc.subjectHygroscopicitypt_BR
dc.subjectBioreducerpt_BR
dc.subjectSteel industrypt_BR
dc.titleEquilibrium moisture content in charcoal exposed to different relative humidity conditionspt_BR
dc.typeArtigopt_BR
Aparece nas coleções:DCF - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.