Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/58758
Título: | Confiabilidade e reprodutibilidade da medida de diferentes manifestações da forca muscular |
Título(s) alternativo(s): | Reliability and reproducibility of the measurement of different muscle strength manifestations |
Palavras-chave: | Saúde Força muscular Potência muscular Health Muscle strength Muscle power |
Data do documento: | 2022 |
Citação: | MARTINS, D. B. M. et al. Confiabilidade e reprodutibilidade da medida de diferentes manifestações da forca muscular. Revista Brasileira de Fisiologia do Exercício, [S.l.], v. 21, n. 5, p. 303-311, 2022. |
Resumo: | Introduction: Studies that evaluate the reproducibility of CVIM and muscle power tests are scarce and often have low practical applicability. Objective: To evaluate the reliability and reproducibility of tests for measuring different manifestations of muscle strength. Methods: Nineteen healthy men, aged 23.36 ± 2.35 years, 1.82 ± 0.06 m and 80.17 ± 11.57 kg, with no experience with resistance training (RT) and no experien-ce with the test protocols performed were evaluated. The volunteers were submitted to two assessments of maximum isometric strength (CVIM), maximum dynamic strength (1RM), and muscle power, respecti-vely, separated by 72 hours. Results: For all muscle strength assessment protocols, an intraclass correlation coefficient (ICC) with high to very high strength of agreement (ICC ≥ 0.79) was found. However, all me-asurements showed a moderate coefficient of variation (CV): CVIM (CV = 12.0%), mean muscle power at 40%, 60%, and 80% of the 1RM (CV = 16.2%, 11, 0% and 14.0% respectively) and peak muscle power (PP) at 60% and 80% of 1RM (CV = 11.8% and 13.3% respectively), except for RM (CV = 6.4%), and PP at 40% of 1RM (CV = 5.8%), with an acceptable measurement standard error (SEM). Conclusion: The high to very high values for the ICC indicate an excellent reliability of the measurements in the different manifestations of muscle strength. However, since the volunteers had no experience with RT, a familiarization process prior to carrying out the tests is recommended, in order to improve their reproducibility indicators. |
URI: | http://repositorio.ufla.br/jspui/handle/1/58758 |
Aparece nas coleções: | DEF - Artigos publicados em periódicos |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
ARTIGO_Confiabilidade e reprodutibilidade da medida de diferentes manifestações da forca muscular.pdf | 213,24 kB | Adobe PDF | Visualizar/Abrir |
Este item está licenciada sob uma Licença Creative Commons