Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/13181
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Faria, Marco Tulio C. | - |
dc.creator | Paulino, Olair Gonçalves | - |
dc.creator | Oliveira, Fernando Henrique de | - |
dc.creator | Barbosa, Bruno Henrique | - |
dc.creator | Martinez, Carlos Barreira | - |
dc.date.accessioned | 2017-06-06T20:55:29Z | - |
dc.date.available | 2017-06-06T20:55:29Z | - |
dc.date.issued | 2010-11 | - |
dc.identifier.citation | FARIA, M. T. C. et al. Influence of mechanical draft tube fish barrier on the hydraulic thrust of small Francis turbines. Journal of Hydraulic Engineering, New York, v. 136, n. 11, Nov. 2010. Não paginado. | pt_BR |
dc.identifier.uri | http://ascelibrary.org/doi/abs/10.1061/%28ASCE%29HY.1943-7900.0000256 | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/13181 | - |
dc.description.abstract | Environmental regulations have required from hydroelectric power plants more effective means of restricting the access of fish into the draft tube of hydraulic turbines. The decline of fish populations on rivers used for electricity generation has motivated the installation of mechanical gates as fish barriers on the tailrace pipe of hydroelectric power plants as a technical solution to preserve aquatic wild life. However, variations in the flow conditions through the turbine runner may modify the performance characteristics of turbines, thus affecting their capacity for electricity production. This note presents an experimental study of the influence of draft tube gates on the hydraulic forces acting on Francis turbines. A Francis turbine test bench was specially designed to allow this investigation. Measurements of the hydraulic thrust in relation to the level of flow restriction at the draft tube exit indicate that the mechanical gates excessively increase the axial load on the runner shaft, which may shorten the hydrogenerator unit life. | pt_BR |
dc.language | en_US | pt_BR |
dc.publisher | American Society of Civil Engineers | pt_BR |
dc.rights | restrictAccess | pt_BR |
dc.source | Journal of Hydraulic Engineering | pt_BR |
dc.subject | Francis turbines | pt_BR |
dc.subject | Fish barries | pt_BR |
dc.subject | Hydraulic turbines | pt_BR |
dc.subject | Turbinas Francis | pt_BR |
dc.subject | Barreiras de peixes | pt_BR |
dc.subject | Turbinas hidráulicas | pt_BR |
dc.title | Influence of mechanical draft tube fish barrier on the hydraulic thrust of small Francis turbines | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DEG - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.