Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/36929
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBraga Junior, Roberto A.-
dc.creatorGonzález-Peña, Rolando J.-
dc.date.accessioned2019-09-25T20:47:20Z-
dc.date.available2019-09-25T20:47:20Z-
dc.date.issued2016-12-
dc.identifier.citationBRAGA JR., R. A.; GONZÁLEZ-PEÑA, R. J. Accuracy in dynamic laser speckle: optimum size of speckles for temporal and frequency analyses. Optical Engineering, [S.l.], v. 55, n. 12, Dec. 2016. DOI: 10.1117/1.OE.55.12.121702.pt_BR
dc.identifier.urihttps://www.spiedigitallibrary.org/journals/Optical-Engineering/volume-55/issue-12/121702/Accuracy-in-dynamic-laser-speckle--optimum-size-of-speckles/10.1117/1.OE.55.12.121702.fullpt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/36929-
dc.description.abstractThe dynamic laser-speckle phenomenon has been used as a potential tool to monitor the activity of many biological and nonbiological samples; however, a key tailoring of the experimental configuration must be taken into account to avoid wrong measurements, since the general rules addressed to speckle as information cannot be directly adopted in dynamic laser-speckle monitoring. The speckle/pixel size ratio is provided by the f-number and by the magnification of the macro lens, and attention is mainly directed toward adjusting a speckle/pixel ratio higher than 1. However, a speckle/pixel ratio much higher than one does not mean an optimum adjustment. This work tested different apertures with fixed magnification yielding to monitor a drying paint process. The outcomes were evaluated in the time and frequency domains. The highest speckle/pixel size ratio was not the best to monitor the process using the dynamic laser speckle under frequency analysis. Tailoring of the devices must take into account the optimum speckle/pixel size ratio, which could vary depending on the application, and the known Nyquist theorem cannot be considered as a sufficient condition since the setup of the optical camera with its macro and iris must also be adjusted in accordance with the frequency response.pt_BR
dc.languageen_USpt_BR
dc.publisherSPIE.orgpt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceOptical Engineeringpt_BR
dc.subjectSpeckle patternspt_BR
dc.subjectDynamic laser specklept_BR
dc.titleAccuracy in dynamic laser speckle: optimum size of speckles for temporal and frequency analysespt_BR
dc.typeArtigopt_BR
Aparece nas coleções:DEG - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.