Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/46797
Registro completo de metadados
Campo DCValorIdioma
dc.creatorJoca, Jhonny Frank Sousa-
dc.creatorFelix, Fabiana da Silva-
dc.creatorAngnes, Lúcio-
dc.date.accessioned2021-07-22T19:07:14Z-
dc.date.available2021-07-22T19:07:14Z-
dc.date.issued2020-
dc.identifier.citationJOCA, J. F. S.; FELIX, F. da S.; ANGNES, L. Ultrasonic-assisted digestion of cement and clinker samples for the determination of manganese by square wave cathodic stripping voltammetry. Analytical Letters, Philadelphia, v. 53, n. 7, p. 1075-1086, 2020. DOI: 10.1080/00032719.2019.1695813.pt_BR
dc.identifier.urihttps://doi.org/10.1080/00032719.2019.1695813pt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/46797-
dc.description.abstractCement and clinker are complex samples and constitute a challenge for elemental analysis. Manganese, usually present in these matrices, can accumulate in bones, liver, the pancreas, kidneys, and brain and its monitoring is very important. This work presents an alternative method of sample treatment based on ultrasonic-assisted extraction for the determination of trace amounts of manganese in cement and clinker samples by square wave cathodic stripping voltammetry (SWCSV) on a gold working electrodes. The proposed extraction procedure occurs at room temperature inside closed vessels and uses 3.0 mol L−1 HCl solution, a less corrosive extractant compared to concentrated acids. Ultrasonic extraction was compared with conventional extraction by heating on hot plate and no significant differences between the two extraction methods were observed at the 95% confidence level. The possible use of H2O2 in the extraction process was evaluated but not used due to its interferences in the electrochemical determination of manganese. The SWCSV results obtained employing 0.20 mol L−1 H3BO3/0.10 mol L−1 KCl electrolyte at pH 6.5 produced two distinct linear regions of concentration for the analytical curve from 1.1 to 2.0 × 10−7 mol L−1 and from 2.0 to 3.2 × 10−7 mol L−1. The limits of detection and quantification were 3.1 × 10−8 mol L−1 and 9.8 × 10−8 mol L−1, respectively, and suitable for the proposed application. The results obtained by SWCSV were consistent with those obtained by flame atomic absorption spectrometry (FAAS) at the 95% confidence level.pt_BR
dc.languageenpt_BR
dc.publisherTaylor & Francis Grouppt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceAnalytical Letterspt_BR
dc.subjectCathodic strippingpt_BR
dc.subjectCementpt_BR
dc.subjectClinkerpt_BR
dc.subjectGold electrodept_BR
dc.subjectManganesept_BR
dc.subjectUltrassompt_BR
dc.subjectSquare wave voltammetrypt_BR
dc.subjectUltrasoundpt_BR
dc.subjectVoltametria de onda quadradapt_BR
dc.subjectDecapagem catódicapt_BR
dc.subjectCimentopt_BR
dc.subjectEletrodo de ouropt_BR
dc.subjectManganêspt_BR
dc.titleUltrasonic-assisted digestion of cement and clinker samples for the determination of manganese by square wave cathodic stripping voltammetrypt_BR
dc.typeArtigopt_BR
Aparece nas coleções:DQI - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.