Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/49226
Registro completo de metadados
Campo DCValorIdioma
dc.creatorBarbosa, Samara Martins-
dc.creatorCarducci, Carla Eloize-
dc.creatorSerafim, Milson Evaldo-
dc.creatorZeviani, Walmes Marques-
dc.creatorAlbach, Breidi-
dc.creatorCastro, Elisa de Melo-
dc.creatorOliveira, Geraldo César de-
dc.date.accessioned2022-02-08T21:20:07Z-
dc.date.available2022-02-08T21:20:07Z-
dc.date.issued2021-09-
dc.identifier.citationBARBOSA, S. M. et al. Using ultrasonic and microwave devices to dry and disperse soils with high Fe2O3 content from Brazil. Geoderma Regional, [S.l.], v. 26, Sept. 2021.pt_BR
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S235200942100064Xpt_BR
dc.identifier.urihttp://repositorio.ufla.br/jspui/handle/1/49226-
dc.description.abstractOur aim was to use the domestic microwave to dry different tropical soils with an iron oxide (Fe2O3) content in the clay fraction, as well as to disperse them using ultrasonic energy. We used nine soils with different Fe2O3 content in the clay fraction (31–663 g kg−1) from horizons (A-Bi-Bw) of the Inceptisols and Oxisols in Brazil. The study was separated into two experiments: 1- soil drying time modeling (classic oven methods v. domestic microwave), 2- Soil dispersion: particle size and clay dispersed in water, by ultrasound energy v. standard method (NaOH 1 N + mechanical dispersion). Data were submitted to Gompertz non-linear regression model, ANOVA, Scott Knott's test, and Pearson's correlations. The domestic microwave was efficient for eigth soils studied, being limited when the Fe2O3 content exceeds 50%. The optimum drying time was between 30 and 40 min. The dispersion carried out by sonification, with the energy of 127.5 Jml−1, in five minutes, increased the clay content, showing greater efficiency in relation to the standard dispersion method, in soils with high Fe2O3 content. The use of the domestic microwave and the ultrasonic to disperse the soil allows a particle size analysis to be carried out in one hour with good precision compared to the standard method.pt_BR
dc.languageen_USpt_BR
dc.publisherElsevierpt_BR
dc.rightsrestrictAccesspt_BR
dc.sourceGeoderma Regionalpt_BR
dc.subjectSoil dryingpt_BR
dc.subjectMathematical modelingpt_BR
dc.subjectSoil dispersionpt_BR
dc.subjectDystrudeptpt_BR
dc.subjectHaplustoxpt_BR
dc.subjectLatossolospt_BR
dc.subjectCambissolospt_BR
dc.titleUsing ultrasonic and microwave devices to dry and disperse soils with high Fe2O3 content from Brazilpt_BR
dc.typeArtigopt_BR
Aparece nas coleções:DCS - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.