Buscar

 

RI UFLA (Universidade Federal de Lavras) >
DQI - Departamento de Química >
DQI - Artigos publicados em periódicos >

Por favor, utilize esse identificador para citar este item ou usar como link: http://repositorio.ufla.br/jspui/handle/1/11254

Título: Determination of tetradifon in brazilian green bell pepper by differential pulse voltammetry
Autor(es): Aleixo, Herbert
Saczk, Adelir Aparecida
Oliveira, Marcelo Firmino de
Okumura, Leonardo Luiz
Publicador: Electrochemical Society
Data de publicação: 14-Jun-2016
Referência: ALEIXO, H. et al. Determination of tetradifon in brazilian green bell pepper by differential pulse voltammetry. Journal of The Electrochemical Society, Baltimore, v. 159, n. 7, p. B775-B781, 2012.
Abstract: Tetradifon, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to green bell pepper crops. In this context, in this work, a reliable and sensitive method for determination of tetradifon in Brazilian green bell pepper samples involving a differential pulse voltammetry (DPV) technique on a glassy carbon electrode is proposed. The electrochemical behavior of tetradifon as followed by cyclic voltammetry (CV) suggests that its reduction occurs via an irreversible five–electron transfer vs. Ag|AgCl, KCl 3 M reference electrode. Very well–resolved diffusion controlled voltammetric peaks have been obtained in a supporting electrolyte solution composed of a mixture of 40% dimethylformamide (DMF), 30% methanol, and 30% NaOH 0.3 mol L−1 at −1.43, −1.57, −1.73, −1.88, and −2.05 V. The proposed DPV method has a good linear response in the 3.00 – 10.0 μmol L−1 range, with a limit of detection (L.O.D) of 0.756 μmol L−1 and 0.831 μmol L−1 in the absence and in the presence of the matrix, respectively. Moreover, improved L.O.D results (0.607 μmol L−1) have been achieved in the absence of DMF from the supporting electrolyte solution. Recovery has been evaluated in five commercial green bell pepper samples, and recovery percentages ranging from 91.0 to 109 have been obtained for tetradifon determinations. The proposed voltammetric method has also been tested for reproducibility, repeatability, and potential interferents, and the results obtained for these three analytical parameters are satisfactory for electroanalytical purposes.
URI: http://jes.ecsdl.org/content/159/7/B775.abstract
http://repositorio.ufla.br/jspui/handle/1/11254
Idioma: en_US
Aparece nas coleções: DQI - Artigos publicados em periódicos

Arquivos neste Item:

Não há arquivos associados para este Item.

Itens protegidos por copyright, com todos os direitos reservados, Salvo indicação em contrário.


Mostrar estatísticas

 


DSpace Software Copyright © 2002-2007 MIT and Hewlett-Packard - Feedback