Título: Voltammetric determination of sulfamethoxazole by nickel hexacyanoferrate film-chemically modified electrode
Palavras-chave: Sulfamethoxazole
Nickel hexacyanoferrate film
Cyclic voltammetry
Chemically modified electrodes
Data do documento: 2018
Citação: ELEOTÉRIO, I. C. et al. Voltammetric determination of sulfamethoxazole by nickel hexacyanoferrate film-chemically modified electrode. World Journal of Pharmaceutical Research, [S.l.], v. 7, n. 5, 2018.
Resumo: Both human and veterinary medicine have relied on the antibiotic sulfamethoxazole to treat infections. However, high consumption of this compound culminates in environmental and public health problems. In this context, here we describe a voltammetric method to determine sulfametoxazole levels, using a glassy carbon disc electrode, chemically modified with nickel hexacyanoferrate film. We prepared the by cyclic voltammetry. The results provided a linear correlation coefficient (r) of 0.998 with a standard deviation (SD) of 0.053 μA, a limit of detection (based on the 3 SD/m ratio) equal to 6.8 nmol L-1, and a limit of quantification (based on the 10 SD/m ratio) of 22.7 nmol L-1.
URI: http://www.wjpr.net/dashboard/abstract_id/9269
http://repositorio.ufla.br/jspui/handle/1/32841
Aparece nas coleções:DQI - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.