Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/38680
Título: Biomechanical comparison of plate-nail vs. plate-rod for experimentally-induced gap fractures in ex vivo canine femora
Data do documento: 2015
Editor: Science Alert
Citação: Asian Journal of Animal Sciences
Resumo: The purpose this original article is to compare the mechanical properties of an interlocking nail-plate combination (plate-nail) vs. an intramedullary pin-plate combination (plate-rod) applied to experimentally induced gap fractures in canine femora. Twenty four paired canine femora were assigned to either plate-nail or plate-rod with 2.7 mm or 3.5 mm system constructs. In each femur, a mid-diaphyseal ostectomy was performed and the selected system was applied. Paired system constructs were subjected to compression and bending tests. The maximum load differed significantly between fixation systems. The plate-nail system had greater maximum load than plate-rod system. The strength, stiffness and maximum deformation was similar between plate-rod and plate-nail. The plate-nail system proved to be a good option for diaphyseal long bone fracture fixation in dogs.
URI: https://scialert.net/abstract/?doi=ajas.2015.361.369
http://repositorio.ufla.br/jspui/handle/1/38680
Aparece nas coleções:DCF - Artigos publicados em periódicos
DMV - Artigos publicados em periódicos

Arquivos associados a este item:
Não existem arquivos associados a este item.


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.