Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/39302
Título: | Wind drift and evaporation losses of a mechanical lateral-move irrigation system: oscillating plate versus fixed spray plate sprinklers |
Palavras-chave: | Sprinkler irrigation Wind speed Wind drift and evaporation losses (WDEL) Superspray I-Wob |
Data do documento: | Nov-2019 |
Editor: | Elsevier |
Citação: | MANKE, E. B. et al. Wind drift and evaporation losses of a mechanical lateral-move irrigation system: oscillating plate versus fixed spray plate sprinklers. Agricultural Water Management, [S.l.], v. 225, Nov. 2019. |
Resumo: | The mechanical lateral-move irrigation system has the capacity to achieve high irrigation efficiency when handled properly; however, during irrigation, wind drift and evaporation losses (WDEL) can occur that are caused by operational and meteorological factors. Thus, the objectives of this study were: to determine the WDEL of a mechanical lateral-move irrigation system fully equipped with oscillating plate sprinklers (I-Wob) under different meteorological conditions; to evaluate the predictive capacity of eight published WDEL models that were compared with field data of the full length mechanical lateral-move irrigation system; to develop a model for estimating the WDEL of a mechanical lateral-move irrigation system equipped with an oscillating plate; and to compare the WDEL and Christiansen Uniformity coefficient for fixed-spray plate (Superspray) and I-Wob under field conditions. The study was conducted using 65 in-field tests that were divided into two groups; the first group of 35 in-field tests used a full-length lateral-move irrigation system equipped with I-Wob sprinklers, and the second group consisted of 30 in-field tests that used only the span 2 (Superspray) and the span 4 I-Wob sprinklers. The WDEL for the full-length lateral-move systems ranged from 4.4 to 25.2%, with an average of 11.6%. A Pearson’s correlation test found that wind speed was significant at a 5% significance level. The proposed model performed better than the eight published models. A comparison of the I-Wob and Superspray sprinklers installed in the mechanical lateral-move irrigation systems indicated that I-WOB performed better and had higher Christiansen’s Uniformity coefficient values and lower wind drift and evaporation losses. |
URI: | https://www.sciencedirect.com/science/article/abs/pii/S0378377419307966 http://repositorio.ufla.br/jspui/handle/1/39302 |
Aparece nas coleções: | DEG - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.