Use este identificador para citar ou linkar para este item: http://repositorio.ufla.br/jspui/handle/1/50527
Título: Nonlinear models for soil moisture sensor calibration in tropical mountainous soils
Palavras-chave: Soil dielectric constant
Soil water content
Model selection
Dielectric-based sensor
Solo - Constante dielétrica
Solo - Umidade
Modelos de regressão
Sensores eletromagnéticos
Data do documento: Jul-2021
Editor: Escola Superior de Agricultura "Luiz de Queiroz" - USP/ESALQ
Citação: SILVA, B. P. C. et al. Nonlinear models for soil moisture sensor calibration in tropical mountainous soils. Scientia Agricola, Piracicaba, v. 79, n. 4, e20200253, 2022. DOI: http://doi.org/10.1590/1678-992X-2020-0253.
Resumo: Electromagnetic sensors are widely used to monitor soil water content (θ); however, site-specific calibrations are necessary for accurate measurements. This study compares regression models used for calibration of soil moisture sensors and investigates the relation between soil attributes and the adjusted parameters of the specific calibration equations. Undisturbed soil samples were collected in the A and B horizons of two Ultisols and two Inceptisols from the Mantiqueira Range in Southeastern Brazil. After saturation, the Theta Probe ML2X was used to obtain the soil dielectric constant (ε). Several readings were made, ranging from saturation to oven-dry. After each reading, the samples were weighted to calculate θ (m3 m–3). Fourteen regression models (linear, linearized, and nonlinear) were adjusted to the calibration data and checked for their residue distribution. Only the exponential model with three parameters met the regression assumptions regarding residue distribution. The stepwise regression was used to obtain multiple linear equations to estimate the adjusted parameters of the calibration model from soil attributes, with silt and clay contents providing the best relations. Both the specific and the general calibrations performed well, with RMSE values of 0.02 and 0.03 m3 m–3, respectively. Manufacturer calibration and equations from the literature were much less accurate, reinforcing the need to develop specific calibrations.
URI: http://repositorio.ufla.br/jspui/handle/1/50527
Aparece nas coleções:DCS - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
ARTIGO_Nonlinear models for soil moisture sensor calibration in tropical mountainous soils.pdf4,43 MBAdobe PDFVisualizar/Abrir