Use este identificador para citar ou linkar para este item:
http://repositorio.ufla.br/jspui/handle/1/58184
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Felix, Fabiana da Silva | - |
dc.creator | Bazzana, Matheus Julien Ferreira | - |
dc.creator | Assis, Letícia Cristina | - |
dc.creator | Mansur, Bethânia Leite | - |
dc.creator | Vieira, Sara Silveira | - |
dc.creator | Magriotis, Zuy Maria | - |
dc.creator | Okumura, Leonardo Luiz | - |
dc.creator | Saczk, Adelir Aparecida | - |
dc.date.accessioned | 2023-07-24T16:05:28Z | - |
dc.date.available | 2023-07-24T16:05:28Z | - |
dc.date.issued | 2023 | - |
dc.identifier.citation | FELIX, F. da S. et al. Development of an electrochemical sensor modified with dealuminated zeolite with citric acid for hydroxyzine determination by BIA-Amperometry. Brazilian Journal of Analytical Chemistry, [S.l.], v. 10, n. 40, p. 65-75, 2023. | pt_BR |
dc.identifier.uri | https://brjac.com.br/artigos/brjac-93-2022.pdf | pt_BR |
dc.identifier.uri | http://repositorio.ufla.br/jspui/handle/1/58184 | - |
dc.description.abstract | An electrochemical sensor modified with zeolite dealuminated with citric acid was developed for the determination of hydroxyzine in pharmaceutical products during BIA-amperometry experiments. The modified electrochemical sensor was prepared by mixing powdered graphite with zeolite treated with citric acid homogenized with hexane and mineral oil (60:20:20% w/w/w respectively). The developed sensor showed reproducible amperometric responses in a linear range of 1.0x10-6 – 2.0x10-5 mol L-1 in +1,28 V (vs. Ag/AgCl). The detection limit and detection limit found were 3.10x10-7 mol L-1 e 1.04x10-6 mol L-1, respectively. The method developed by BIA-amperometry was applied for the determination of the analyte in tablets and commercial syrups and the results found agreement with the nominal values of the commercial samples. | pt_BR |
dc.language | en_US | pt_BR |
dc.publisher | Visão Fokka Communication Agency | pt_BR |
dc.rights | restrictAccess | pt_BR |
dc.source | Brazilian Journal of Analytical Chemistry | pt_BR |
dc.subject | Batch Injection analysis | pt_BR |
dc.subject | Amperometric sensor | pt_BR |
dc.subject | Carbon paste electrodes | pt_BR |
dc.subject | Hydroxyzine | pt_BR |
dc.subject | Zeolite | pt_BR |
dc.title | Development of an electrochemical sensor modified with dealuminated zeolite with citric acid for hydroxyzine determination by BIA-Amperometry | pt_BR |
dc.type | Artigo | pt_BR |
Aparece nas coleções: | DQI - Artigos publicados em periódicos |
Arquivos associados a este item:
Não existem arquivos associados a este item.
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.