Determination of tetradifon in brazilian green bell pepper by differential pulse voltammetry

dc.creatorAleixo, Herbert
dc.creatorSaczk, Adelir Aparecida
dc.creatorOliveira, Marcelo Firmino de
dc.creatorOkumura, Leonardo Luiz
dc.date.accessioned2016-06-14T13:38:55Z
dc.date.available2016-06-14T13:38:55Z
dc.date.issued2016-06-14
dc.description.abstractTetradifon, a potentially carcinogenic and mutagenic pesticide, can contribute to environmental and human contamination when applied to green bell pepper crops. In this context, in this work, a reliable and sensitive method for determination of tetradifon in Brazilian green bell pepper samples involving a differential pulse voltammetry (DPV) technique on a glassy carbon electrode is proposed. The electrochemical behavior of tetradifon as followed by cyclic voltammetry (CV) suggests that its reduction occurs via an irreversible five–electron transfer vs. Ag|AgCl, KCl 3 M reference electrode. Very well–resolved diffusion controlled voltammetric peaks have been obtained in a supporting electrolyte solution composed of a mixture of 40% dimethylformamide (DMF), 30% methanol, and 30% NaOH 0.3 mol L−1 at −1.43, −1.57, −1.73, −1.88, and −2.05 V. The proposed DPV method has a good linear response in the 3.00 – 10.0 μmol L−1 range, with a limit of detection (L.O.D) of 0.756 μmol L−1 and 0.831 μmol L−1 in the absence and in the presence of the matrix, respectively. Moreover, improved L.O.D results (0.607 μmol L−1) have been achieved in the absence of DMF from the supporting electrolyte solution. Recovery has been evaluated in five commercial green bell pepper samples, and recovery percentages ranging from 91.0 to 109 have been obtained for tetradifon determinations. The proposed voltammetric method has also been tested for reproducibility, repeatability, and potential interferents, and the results obtained for these three analytical parameters are satisfactory for electroanalytical purposes.pt_BR
dc.identifier.citationALEIXO, H. et al. Determination of tetradifon in brazilian green bell pepper by differential pulse voltammetry. Journal of The Electrochemical Society, Baltimore, v. 159, n. 7, p. B775-B781, 2012.pt_BR
dc.identifier.urihttps://repositorio.ufla.br/handle/1/11254
dc.identifier.urihttp://jes.ecsdl.org/content/159/7/B775.abstractpt_BR
dc.languageen_USpt_BR
dc.publisherElectrochemical Societypt_BR
dc.rightsopenAccesspt_BR
dc.sourceJournal of The Electrochemical Societypt_BR
dc.titleDetermination of tetradifon in brazilian green bell pepper by differential pulse voltammetrypt_BR
dc.typeArtigopt_BR

Arquivos

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
953 B
Formato:
Item-specific license agreed upon to submission
Descrição: