Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling

dc.creatorAndrade, Rafaella R.
dc.creatorTinôco, Ilda de Fátima F.
dc.creatorDamasceno, Flávio A.
dc.creatorFerraz, Gabriel A. S.
dc.creatorFreitas, Letícia Cibele S. R.
dc.creatorFerreira, Cecília de Fátima S.
dc.creatorBarbari, Matteo
dc.creatorTeles Junior, Carlos G. S.
dc.date.accessioned2022-11-03T20:11:48Z
dc.date.available2022-11-03T20:11:48Z
dc.date.issued2022
dc.description.abstractIn this study, we aimed to assess the spatial variability of microclimate inside a closed compost-bedded pack barn (CBP) with a negative ventilation system during summer and winter. The research was carried out in a CBP located in the Zona da Mata region, Minas Gerais, Brazil. For each of the stations analyzed, the following environmental mean variables observed inside a CBP were measured: air dry-bulb temperature (tdb), air relative humidity (RH), and windspeed, Temperature-Humidity index, and specific enthalpy. The kriging maps showed that the most critical housing conditions in the thermal environment were found, mainly, from the central part of the CBP, close to the exhaust fans. The analyses also pointed out that the system presented temperature gradients along the length, up to 3°C. During the summer afternoon, the entire region of the CBP was in a discomfort situation (tdb>26°C; RH>75%). During the winter, the measured environmental data remained within the comfort zone throughout the facility. However, probably due to the lack of thermal insulation of the material used to close the sides of the CBP, it did not allow spatial thermal uniformity for both seasons. It was also inefficient to keep the animals within the comfort zone for lactating cattle during the critical summer period.pt_BR
dc.identifier.citationANDRADE, R. R. et al. Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling. Anais da Academia Brasileira de Ciências, Rio de Janeiro, v. 94, n. 3, p. 1-23, 2022. DOI: 10.1590/0001-3765202220210226.pt_BR
dc.identifier.urihttps://repositorio.ufla.br/handle/1/55401
dc.languageen_USpt_BR
dc.rightsAttribution 4.0 International*
dc.rightsAttribution 4.0 International
dc.rightsacesso abertopt_BR
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.sourceAnais da Academia Brasileira de Ciênciaspt_BR
dc.subjectAnimal welfarept_BR
dc.subjectCompost barnspt_BR
dc.subjectDairy cattlept_BR
dc.subjectEvaporative coolingpt_BR
dc.subjectHeat stresspt_BR
dc.subjectModel-based geostatisticspt_BR
dc.titleSpatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel coolingpt_BR
dc.typeArtigopt_BR

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
ARTIGO_Spatial analysis of microclimatic variables in compost-bedded pack barn with evaporative tunnel cooling.pdf
Tamanho:
4.52 MB
Formato:
Adobe Portable Document Format
Descrição:

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
953 B
Formato:
Item-specific license agreed upon to submission
Descrição: