Artigo

Zoneamento do potencial de uso de sistemas de resfriamento evaporativo no sudeste brasileiro

Carregando...
Imagem de Miniatura

Notas

Data

Orientadores

Editores

Coorientadores

Membros de banca

Título da Revista

ISSN da Revista

Título de Volume

Editor

Universidade Federal de Campina Grande

Faculdade, Instituto ou Escola

Departamento

Programa de Pós-Graduação

Agência de fomento

Tipo de impacto

Áreas Temáticas da Extenção

Objetivos de Desenvolvimento Sustentável

Dados abertos

Resumo

O zoneamento do potencial de uso de sistemas de resfriamento evaporativo (SRE) acoplado a um sistema de ventilação em modo túnel (SVT) foi realizado no presente trabalho, com vistas à criação de frangos de corte na região Sudeste do Brasil. Quatro configurações do sistema foram testadas: a) SVT; b) SVT associado à SRE do tipo material poroso umedecido com 40% de eficiência (SVTPAD40); c) SVT associado à SRE do tipo material poroso umedecido com 70% de eficiência (SVTPAD70) e d) SVTPAD70 associado a sistema de nebulização (SVTPAD70+NEB). O ambiente térmico foi caracterizado por meio do índice de temperatura e umidade, enquanto o desempenho das aves foi determinado pelo consumo de ração diário, ganho de peso diário e conversão alimentar. Dados meteorológicos de 1980 a 2001, disponibilizados pelo Projeto Reanálise-2 do NCEP/NCAR, foram utilizados nesta pesquisa. Verificou-se o efeito benéfico do uso dos SRE, com SVTPAD70+NEB proporcionando as melhores condições de produção, em especial nos meses de setembro e outubro para quase toda a região Sudeste, com destaque para as mesorregiões Norte e Noroeste de Minas Gerais.

Abstract

In present research the potential use of evaporative cooling systems (ECS) associated to tunnel ventilation system (TVS) for broiler reared in Southeastern Brazil was studied. Four configuration systems were tested: (a) TVS, (b) TVS associated to a pad cooling system with 40% efficiency (TVSPAD40), (c) TVS associated to a pad cooling system with 70% efficiency (TVSPAD70) and (d) TVSPAD70 associated to a misting system (TVSPAD70+MIST). Thermal environment was characterized by temperature-humidity index, and the chicken performance was estimated by daily feed intake, daily weight gain and feed conversion. Climatic data from 1980 to 2001, released through Reanalysis-2 Project from NCEP/NCAR were used in this research. The benefitial effect of the use of ECS with TVSPAD70+MIST for providing better production condition was verified, especially during September and October for almost all the southeastern region, mainly in northern and northwestern part of the Minas Gerais State.

Descrição

Área de concentração

Agência de desenvolvimento

Palavra chave

Marca

Objetivo

Procedência

Impacto da pesquisa

Resumen

ISBN

DOI

Citação

CARVALHO, V. F. et al. Zoneamento do potencial de uso de sistemas de resfriamento evaporativo no sudeste brasileiro. Revista Brasileira de Engenharia Agrícola e Ambiental, Campina Grande, v. 13, n. 3, p. 358-366, 2009.

Link externo

Avaliação

Revisão

Suplementado Por

Referenciado Por

Licença Creative Commons

Exceto quando indicado de outra forma, a licença deste item é descrita como Attribution-NonCommercial 4.0 International