O zoneamento do potencial de uso de sistemas de resfriamento evaporativo (SRE) acoplado a um sistema de ventilação
em modo túnel (SVT) foi realizado no presente trabalho, com vistas à criação de frangos de corte na região Sudeste do
Brasil. Quatro configurações do sistema foram testadas: a) SVT; b) SVT associado à SRE do tipo material poroso umedecido com 40% de eficiência (SVTPAD40); c) SVT associado à SRE do tipo material poroso umedecido com 70% de eficiência (SVTPAD70) e d) SVTPAD70 associado a sistema de nebulização (SVTPAD70+NEB). O ambiente térmico foi caracterizado
por meio do índice de temperatura e umidade, enquanto o desempenho das aves foi determinado pelo consumo de
ração diário, ganho de peso diário e conversão alimentar. Dados meteorológicos de 1980 a 2001, disponibilizados pelo
Projeto Reanálise-2 do NCEP/NCAR, foram utilizados nesta pesquisa. Verificou-se o efeito benéfico do uso dos SRE, com
SVTPAD70+NEB proporcionando as melhores condições de produção, em especial nos meses de setembro e outubro para
quase toda a região Sudeste, com destaque para as mesorregiões Norte e Noroeste de Minas Gerais.
Abstract
In present research the potential use of evaporative cooling systems (ECS) associated to tunnel ventilation system (TVS)
for broiler reared in Southeastern Brazil was studied. Four configuration systems were tested: (a) TVS, (b) TVS associated
to a pad cooling system with 40% efficiency (TVSPAD40), (c) TVS associated to a pad cooling system with 70% efficiency
(TVSPAD70) and (d) TVSPAD70 associated to a misting system (TVSPAD70+MIST). Thermal environment was characterized by
temperature-humidity index, and the chicken performance was estimated by daily feed intake, daily weight gain and
feed conversion. Climatic data from 1980 to 2001, released through Reanalysis-2 Project from NCEP/NCAR were used
in this research. The benefitial effect of the use of ECS with TVSPAD70+MIST for providing better production condition was
verified, especially during September and October for almost all the southeastern region, mainly in northern and
northwestern part of the Minas Gerais State.
Descrição
Área de concentração
Agência de desenvolvimento
Palavra chave
Marca
Objetivo
Procedência
Impacto da pesquisa
Resumen
Palavras-chave
ISBN
DOI
Citação
CARVALHO, V. F. et al. Zoneamento do potencial de uso de sistemas de resfriamento evaporativo no sudeste brasileiro. Revista Brasileira de Engenharia Agrícola e Ambiental, Campina Grande, v. 13, n. 3, p. 358-366, 2009.
Link externo
Avaliação
Revisão
Suplementado Por
Referenciado Por
Licença Creative Commons
Exceto quando indicado de outra forma, a licença deste item é descrita como Attribution-NonCommercial 4.0 International