Artigo
Impact of Plasma-Lyte pH 7.4 on acid-base status and hemodynamics in a model of controlled hemorrhagic shock
Carregando...
Notas
Data
Orientadores
Editores
Coorientadores
Membros de banca
Título da Revista
ISSN da Revista
Título de Volume
Editor
Universidade de São Paulo
Faculdade, Instituto ou Escola
Departamento
Programa de Pós-Graduação
Agência de fomento
Tipo de impacto
Áreas Temáticas da Extenção
Objetivos de Desenvolvimento Sustentável
Dados abertos
Resumo
Abstract
OBJECTIVE: Intravenous infusion of crystalloid solutions is a cornerstone of the treatment of hemorrhagic shock. However, crystalloid solutions can have variable metabolic acid-base effects, perpetuating or even aggravating shock-induced metabolic acidosis. The aim of this study was to compare, in a controlled volume-driven porcine model of hemorrhagic shock, the effects of three different crystalloid solutions on the hemodynamics and acid-base balance.
METHODS: Controlled hemorrhagic shock (40% of the total blood volume was removed) was induced in 18 animals, which were then treated with normal saline (0.9% NaCl), Lactated Ringer's Solution or Plasma-Lyte pH 7.4, in a blinded fashion (n = 6 for each group). Using a predefined protocol, the animals received three times the volume of blood removed.
RESULTS: The three different crystalloid infusions were equally capable of reversing the hemorrhage-induced low cardiac output and anuria. The Lactated Ringer's Solution and Plasma-Lyte pH 7.4 infusions resulted in an increased standard base excess and a decreased serum chloride level, whereas treatment with normal saline resulted in a decreased standard base excess and an increased serum chloride level. The Plasma-Lyte pH 7.4 infusions did not change the level of the unmeasured anions.
CONCLUSION: Although the three tested crystalloid solutions were equally able to attenuate the hemodynamic and tissue perfusion disturbances, only the normal saline induced hyperchloremia and metabolic acidosis.
Descrição
Área de concentração
Agência de desenvolvimento
Palavra chave
Marca
Objetivo
Procedência
Impacto da pesquisa
Resumen
ISBN
DOI
Citação
NORITOMI, D. T. et al. Impact of Plasma-Lyte pH 7.4 on acid-base status and hemodynamics in a model of controlled hemorrhagic shock. Clinics, São Paulo, v. 66, n. 11, p. 1969-1974, 2011.