Artigo

Validity and reliability of a new field test (Carminatti's test) for soccer players compared with laboratory-based measures

Carregando...
Imagem de Miniatura

Notas

Data

Orientadores

Editores

Coorientadores

Membros de banca

Título da Revista

ISSN da Revista

Título de Volume

Editor

Taylor & Francis

Faculdade, Instituto ou Escola

Departamento

Programa de Pós-Graduação

Agência de fomento

Tipo de impacto

Áreas Temáticas da Extenção

Objetivos de Desenvolvimento Sustentável

Dados abertos

Resumo

Abstract

The aim of this study was to assess the validity (Study 1) and reliability (Study 2) of a novel intermittent running test (Carminatti's test) for physiological assessment of soccer players. In Study 1, 28 players performed Carminatti's test, a repeated sprint ability test, and an intermittent treadmill test. In Study 2, 24 players performed Carminatti's test twice within 72 h to determine test–retest reliability. Carminatti's test required the participants to complete repeated bouts of 5 × 12 s shuttle running at progressively faster speeds until volitional exhaustion. The 12 s bouts were separated by 6 s recovery periods, making each stage 90 s in duration. The initial running distance was set at 15 m and was increased by 1 m at each stage (90 s). The repeated sprint ability test required the participants to perform 7 × 34.2 m maximal effort sprints separated by 25 s recovery. During the intermittent treadmill test, the initial velocity of 9.0 km · h−1 was increased by 1.2 km · h−1 every 3 min until volitional exhaustion. No significant difference (P > 0.05) was observed between Carminatti's test peak running velocity and speed at VO2max (v-VO2max). Peak running velocity in Carminatti's test was strongly correlated with v-VO2max (r = 0.74, P < 0.01), and highly associated with velocity at the onset of blood lactate accumulation (r = 0.63, P < 0.01). Mean sprint time was strongly associated with peak running velocity in Carminatti's test (r = −0.71, P < 0.01). The intraclass correlation was 0.94 with a coefficient of variation of 1.4%. In conclusion, Carminatti's test appears to be avalid and reliable measure of physical fitness and of the ability to perform intermittent high-intensity exercise in soccer players.

Descrição

Área de concentração

Agência de desenvolvimento

Palavra chave

Marca

Objetivo

Procedência

Impacto da pesquisa

Resumen

ISBN

DOI

Citação

SILVA, J. F. da et al. Validity and reliability of a new field test (Carminatti's test) for soccer players compared with laboratory-based measures. Journal of Sports Sciences, London, v. 29, n. 15, p. 1621-1628, 2011.

Link externo

Avaliação

Revisão

Suplementado Por

Referenciado Por