Semitendinosus (ST) muscle steaks were grouped according to three locations (proximal, middle, and distal end), grilled to endpoint temperature of 71C or cooked for 20, 30, 40, 50, or 60 s in a microwave oven (Mw). The location did not affect (p > .05) the cooking loss (CL) or shear force (SF) values. The CL increased (p < .05) with longer microwave cooking times, but only the Mw40 samples did not differ (p > .05) from the grill samples. None of the microwaves' SF values were different (p > .05) from the grill values, with treatments Mw30 to Mw50 showing moderate repeatability (R = 0.51–0.60) and Mw30 and Mw60 showing higher correlations (r > .71) with grill values. Cooking beef strips with a microwave is a potential method for tenderness evaluation, but requires additional study to evaluate and optimize this application in different muscles and for comparison to sensorial data.
Descrição
Área de concentração
Agência de desenvolvimento
Palavra chave
Marca
Objetivo
Procedência
Impacto da pesquisa
Resumen
Palavras-chave
ISBN
DOI
Citação
SILVA, D. R. G. et al. Microwave as a rapid cooking method for beef tenderness evaluation. Journal of Texture Studies, [S.l.], v. 49, p. 448-455, 2018.